Residual Current Circuit Breaker 4 Poles Type-A 63A 500mA 230-400V IP20 Hager
Four-pole RCCB that provides protection against fault currents in electrical installations and helps reduce the risk of electrical accidents and fire.
Watch this product and we will notify you once it is back in stock.
Residual Current Circuit Breaker 4 Poles Type-A 63A 500mA 230-400V IP20 Hager
Descripton
Four-pole residual current circuit breaker (RCCB) that provides protection against fault currents in electrical installations and helps reduce the risk of electrical accidents and fire. The device continuously monitors the difference between incoming and outgoing current and automatically breaks the current when a fault current exceeds the nominal sensitivity of 500 mA. The residual current circuit breaker is of type A and can detect both alternating current faults and pulsating direct current components. It is intended for mounting on DIN rail in electrical panels and is suitable for use in residential, commercial properties and industrial installations where reliable earth fault protection is required.
Specifications
- Number of poles: 4P
- Number of poles: 4
- Rated current: 63 A
- Rated residual current Idn: 500 mA
- Making and breaking capacity Idm: 1.50 kA
- Rated conditional short-circuit current Inc according to EN 61008-1: 6 kA
- Rated current -25°C: 63 A
- Rated current at -20°C: 63 A
- Rated current -15°C: 63 A
- Rated current -10°C: 63 A
- Rated current -5°C: 63 A
- Rated current at 0°C: 63 A
- Rated current 5°C: 63 A
- Rated current 10°C: 63 A
- Rated current 15°C: 63 A
- Rated current at 20°C: 63 A
- Rated current 25°C: 63 A
- Rated current 30°C: 63 A
- Rated current 35°C: 63 A
- Rated current at 40°C: 63 A
- Rated current at 45°C: 60 A
- Rated current at 50°C: 58 A
- Rated current 55°C: 55 A
- Rated current 60°C: 51 A
- Rated current 65°C: 48 A
- Rated current 70°C: 45 A
- Nominal tightening torque upper connection: 2.80 - 2.80 Nm
- Nominal tightening torque lower connection: 2.80 - 2.80 Nm
- Type of upper connection on standard components: Screw connection
- Type of lower connection on standard components: BIConnect
- Nominal tightening torque: 2.80 - 2.80 Nm
- Rated operating voltage Ue: 230 - 400 V
- Rated insulation voltage Ui: 500 V
- Rated impulse withstand voltage Uimp: 4000 V
- Max. operating voltage (Umax): 440 V
- Frequency: 50 - 50 Hz
- Number of modules: 4
- Protection class (IP): IP20
- Connection area input and output with screws, solid conductor: 1 - 25 mm²
- Connection area input and output with screws, flexible conductor: 1 - 16 mm²
- Area flexible conductor: 16 mm²
- Area solid conductor: 25 mm²
- Connection type: Screw terminal
- Top connection for standard components: Adapted terminal block
- Down connection for standard components: Adapted terminal block
- Total power loss at nominal rated current: 19.70 W
- Operating conditions:
- Max. altitude: 2000 m
- Mechanical life (electrical switching): 2000
- Mechanical life (switching): 4000
- Height: 83 mm
- Width: 70 mm
- Depth: 70 mm