Residual Current Circuit Breaker Acti9 RED 2Poles Type-A 25A 30mA 230V IP20 Schneider Electric
Residual current circuit breaker with recloser, 2 poles, protects against electrical shock by direct or indirect contact and fire hazards.
Watch this product and we will notify you once it is back in stock.
Residual Current Circuit Breaker Acti9 RED 2Poles Type-A 25A 30mA 230V IP20 Schneider Electric
Description
This Acti9 REDs is a modular residual current circuit breaker (RCCB) with recloser. It is a 2Poles circuit breaker with 25A In rated current, 30mA earth leakage sensitivity and A type protection class. This product protects against electrical shock by direct or indirect contact and fire hazards. It disconnects of on-load electric circuits already protected against overloads and short-circuits. It restarts automatically after insulation monitoring of the downstream circuit. It is only used on TT and TN-S earthing grounding systems. The Acti9 REDs and REDtest versions are dedicated to tertiary, industrial and infrastructure applications. This product is compliant with IEC/EN 61008-1 standard. The (Im/IΔm) rated breaking and making short circuit capacity is 630A. The (Inc/IΔc) conditional rated short circuit current is 6kA. It has a mechanical endurance going up to 1000 cycles. The Ue operational voltage is 230VAC. The Ui rated insulation voltage is 500VAC. The Uimp rated impulse withstand voltage is 4kV. The width in 9mm pitches is 10. According to IEC 60529 standard, the degree of protection is IP20 and IP40 in enclosure. The operating temperature is from -5°C to 40°C. The storage temperature is from -20°C to 60°C.
Technical Information
- Mounting method: DIN rail
- Voltage type: AC
- Built-in depth: 44 mm
- Rated current: 25 A
- Rated voltage: 230 V
- Rated insulation voltage Ui: 500 V
- Number of poles: 2
- Rated fault current: 30 A
- Leakage current type: A
- Selective protection: No
- Short-circuit breaking capacity (Icw): 6 kA
- Surge current capacity: 0.25 kA
- Pollution degree: 2
- Width in number of modular spacings: 5
- Short-time delayed tripping: No
- Explosion-proof: No
- Frequency: 50 Hz
- Degree of protection (IP): IP20
- Connectable conductor cross section solid-core: 1.5-2.5 mm²
- Connectable conductor cross section multi-wired: 1.5-2.5 mm²
- With interlocking device: Yes
- Ambient temperature during operating -5-40 °C
- Additional equipment possible: Yes
- Rated impulse withstand voltage Uimp: 4 kV
Specifications
- Measure (WxHxD): 89.2x115x79.5 mm